Monitoring Gastrointestinal Mucosal Perfusion by Tissue Capnometryin Anaesthesiology and Intensive Therapy

P Palágyi - 2016 - search.proquest.com
used for monitoring the partial pressure of carbon dioxide (… The new, quick equilibrating,
silicone rubber gastric tonometer … vitro parallel air tonometric measurements comparing the CO2

Contributions Toward Urinary Carbon Dioxide Monitoring: Sensor Development, Validation, and Utilization

JG Atherton - 2022 - search.proquest.com
… the CO2 values measured in CO2 containing buffer solutionstonometry and monitoring
urinary carbon dioxide (U-CO2), we … open to air and stirred with a magnetic stir bar was used as …

[HTML][HTML] Impairment of Mesenteric Perfusion as a Marker of Major Bleeding in Trauma Patients

P Jávor, T Donka, T Horváth, L Sándor, L Török… - Journal of Clinical …, 2023 - mdpi.com
… The measurement of the partial pressure of carbon dioxide (… Tonometry utilizes the principle
that at equilibrium the partial … After luminal pCO 2 equilibrates the fluid or air in the balloon, …

Evaluation of Toxicity and Antiulcer Activity of Ethanolic Extract of Echinopsechinatusroxb

SR Syedikramsharif - 2018 - repository-tnmgrmu.ac.in
… of carbon dioxide and water to give carbonic acid, which … chloride salt reacts with the
bicarbonate from the intestinal juices to … The third part of the system is a tonometer calibrated upto …

[HTML][HTML] Hypothesis: potentially systemic impacts of elevated CO2 on the human proteome and health

CM Duarte, Ł Jaremko, M Jaremko - Frontiers in public health, 2020 - frontiersin.org
… to the pCO 2 (partial pressure of carbon dioxide) in the ambient … CO 2 concentration in
ambient air is used to promote pre-… CO 2 leads to increased gastric-acid secretion, increased …

Antiulcer Activity of Fresh Rhizome Juice of Curcuma Amada

M Sandeep - 2016 - repository-tnmgrmu.ac.in
… Large uptakes of salt have been linked to higher risk of stomachGastric mucus: It is secreted
by mucus neck cells of the … The third part of the system is a tonometer calibrated up to 1 bar. …

The development of novel biomarker techniques for the early detection of colorectal anastomotic breakdown

EC Wright - 2019 - theses.gla.ac.uk
Partial pressure of carbon dioxide PCT … Partial pressure of oxygen POSSUM … The
intraperitoneal gastrointestinal tract consists of 4 layers: mucosa, submucosa, muscularis propria and …

SURGICAL BIOLOGY SECTION

K Mitchell, A Schoster - Equine Surgery-E-Book: Equine Surgery …, 2018 - books.google.com
… Physiologic saline solution (0.9% NaCl) differs in that it … techniques include gastric
tonometry, which evaluates CO … by a partial pressure of carbon dioxide in arterial blood (Paco2…

Fluid balance

R Kirby, E Rudloff - Monitoring and Intervention for the Critically …, 2016 - Wiley Online Library
… Elevated tonometry values and gradients between mucosal … Normal saline (0.9% sodium
chloride) solution is an IRC with … circulating blankets or forced air heating blankets should begin …

[PDF][PDF] 8 Pathophysiology and Management of Shock

A Kudalkar, B Gupta - Trauma Anesthesia, 2016 - ndl.ethernet.edu.et
… infarction, fat or air embolism and diaphragmatic rupture with … salt solution should be preferred
over saline-based solution. … (pHi) can be monitored by gastric tonometry. Normal pHi is 7.4 …